Powered by Accton EC3802-WDM Media Converter Installation Guide www.edge-core.
Installation Guide FTTH Media Converter - EC3802-WDM with One Fixed 100BASE-BX Single-Fiber Line Connection, and One 10BASE-T / 100BASE-TX (RJ-45) Port
EC3802-WDM E012008/ST-R01 150200065000A
Compliances and Safety Warnings FCC - Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio communications.
CE Mark Declaration of Conformance for EMI and Safety (EEC) This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC.
Safety Compliance Warning: Fiber Optic Port Safety When using a fiber optic port, never look at the transmit laser while it is powered on. Also, never look directly at the fiber TX port and fiber cable ends when they are powered on. Avertissment: Ports pour fibres optiques - sécurité sur le plan optique DISPOSITIF LASER DE CLASSE I Ne regardez jamais le laser tant qu'il est sous tension.
About This Guide Purpose This guide details the hardware features of this device, including the physical and performance-related characteristics, and how to install it. Audience The guide is intended for use by network administrators who are responsible for installing and setting up network equipment; consequently, it assumes a basic working knowledge of LANs (Local Area Networks).
Contents Introduction Key Features Description of Hardware Fiber Cable Connection UTP Port Power Connector External DIP Switch Settings LED Indicators Installing the FTTH CPE Package Contents System Requirements Mounting the CPE Desktop Mounting Wall Mounting Connecting to the CPE Making a Connection to the UTP Port Powering On the CPE Configuring the TCP/IP Protocol Windows 95/98/NT Windows 2000 Windows XP Mac OS Systems 11 12 13 13 14 14 15 16 17 17 17 18 19 19 20 20 21 21 21 21 22 22 Product Specificat
Contents x
Introduction Fiber-To-The-Home (FTTH) has always been an attractive option for Internet access. It has all the benefits of optical fiber. It provides a future-proof network, in that you do not have to go through the hassles of upgrading from ADSL to xDSL, or digital co-ax to digital wireless. It does not have to struggle with electromagnetic interference problems, and with no active “outside-plant” components, it offers the highest reliability.
Introduction Key Features • • • • • • • • • • High-speed Internet access Optical fiber port supports transmission distances up to 15 km (9.
Description of Hardware Description of Hardware The EC3802-WDM is an FTTH CPE product for high-speed Internet access applications. This CPE includes an embedded fiber cable connection, an RJ-45 Ethernet LAN port, PoE on the LAN port, a DIP-switch for LAN port settings, LED status indicators, and an AC power adapter connection. The following figure shows the components of the CPE.
Description of Hardware UTP Port The RJ-45 Ethernet port labeled “UTP” operates at 10 or 100 Mbps, and supports auto-negotiation of speed, duplex mode (i.e., half or full duplex), flow control, and MDI/X pinout selection. Automatic configuration of MDI or MDI-X pinout operation, allows you to use straight-through cable for all connections. Where necessary, the UTP port can also be forced to a specific speed and duplex mode via a DIP-switch setting.
Description of Hardware External DIP Switch Settings The CPE has a four-bit DIP switch located on its rear panel next to the UTP port (see figure below). The DIP switch allows you to enable/disable auto-negotiation for the UTP port and manually force the speed and duplex mode setting. Also, there is one switch for enabling link down notification for the fiber connection. Note that the ON position for the DIP switch is down.
Description of Hardware LED Indicators The CPE includes seven LED status indicators on the top panel. The LEDs are detailed in the following figure and table. LED Description PWR ON: Power is on. OFF: Power is off. OPT ON: Fiber link is up. OFF: Fiber link down. TEST ON: Loopback test in progress. OFF: No loopback test (normal mode). PoE ON: PoE is enabled on the LAN port. OFF: PoE is disabled on the LAN port. Link ON: UTP port link is up. Flashing: UTP port is transmitting or receiving data.
Installing the FTTH CPE Installing the FTTH CPE Before installing the CPE, verify that you have all the items listed under “Package Contents.” If any of the items are missing or damaged, contact your service provider. Also, be sure you have all the necessary tools and cabling before installing the CPE.
Installing the FTTH CPE Mounting the CPE Caution: The EC3802-WDM CPE is for indoor mounting only. Do not mount the unit on the outside of a building. The CPE includes rubber feet for desktop mounting. Horizontal mounting using rubber feet Desktop Mounting Wall mounting using the wall-mounting slots Wall Mounting Before you start installing the CPE, make sure you can provide the right operating environment.
Installing the FTTH CPE Desktop Mounting The CPE can be mounted horizontally on any flat surface, such as a desktop or shelf. For horizontal mounting, simply stick the self-adhesive rubber foot pads (that come with this package) on each of the four concave spaces located on the bottom of the CPE. Then, place the CPE on the flat surface where it is to be installed. Rubber feet Bottom surface Wall Mounting The CPE can also be mounted on a wall.
Installing the FTTH CPE Connecting to the CPE Caution: The CPE fiber line should be connected to the unit by a qualified technician only. Do not attempt to remove the fiber cable from the CPE. If there are any problems with the fiber cable connection, contact your service provider. You can connect any computer with an Ethernet network interface card, a LAN switch, hub, or other network device to the CPE’s UTP port.
Installing the FTTH CPE Notes: 1. Make sure each twisted-pair cable does not exceed 100 meters (328 feet). 2. We advise using Category 5 cable for all network connections to avoid any confusion or inconvenience in the future when you upgrade devices to Fast Ethernet. Powering On the CPE Plug the AC power adapter directly into a power outlet. Check the LED marked “PWR” on the front panel to be sure it is on.
Installing the FTTH CPE Windows XP 1. Select Start/Settings/Control Panel. 2. Click on the Network and Internet Connections icon. 3. Double click “LAN or High-Speed Internet.” 4. Click on “Properties.” 5. Double click “Internet Protocol (TCP/IP).” 6. Select the option “Obtain an IP Address automatically.” Mac OS Systems 1. Pull down the Apple Menu. Click “Control Panels” and select “TCP/IP.” 2. In the TCP/IP dialog box, make sure that “Ethernet” is selected in the “Connect via:” field. 3.
Product Specifications Product Specifications Standards Conformance Fiber Specifications Fiber Cable Connector Wavelengths Data Rate Transmit Power Receive Power Optical Power Budget Range Ports Media Connection LEDs Dimensions Weight Media Converter AC Adapter Input Power Available Adapters: Power Consumption Power-over-Ethernet Environmental Temperature Humidity Certification Immunity Emissions Safety IEEE 802.3-2005 Ethernet, Fast Ethernet, Full-duplex flow control ITU-T G.
Troubleshooting Troubleshooting Diagnosing CPE Indicators The FTTH CPE can be easily monitored through panel indicators to identify problems. The table below describes common problems you may encounter and possible solutions. Symptom Cause Solution PWR indicator does Power outlet, or external • Check the power outlet by plugging in another device not light up after power AC power adapter may that is functioning properly. on. be defective. • PoE power to the CPE may be not be supplied to the LAN port.
Upgrading Firmware Upgrading Firmware You can upgrade new CPE software from a local file on a PC attached to the LAN port. New software may be provided periodically from your distributor. The IP address for the CPE’s web interface is 192.168.252.1. Before upgrading new software, verify that your PC is configured with an IP address within the same network subnet (that is, 192.168.252.x). Note: The Status page provides information on the CPE’s IP address, MAC address, hardware version, and serial number.
Port and Cable Assignments 5. Click Apply to start the download process. After the download process is completed, the following message will be displayed. Upgrade Successful, Rebooting ... Please wait a minium of 30 seconds while the system restarts. 6. After the system restarts, the Default Page is displayed. Click System, and then click Firmware Upgrade to verify that the new firmware is now loaded in the CPE.
Port and Cable Assignments Straight-Through Wiring If the twisted-pair cable is to join two ports and only one of the ports has an internal crossover (MDI-X), the two pairs of wires must be straight-through. (The CPE RJ-45 port auto-negotiates MDI or MDI-X pinout selection, allowing you to use either straight-thorough or crossover cable when connecting to another network device.
Port and Cable Assignments 28
EC3802-WDM E012008/ST-R01 150200065000A