CLOUDLAB SERIES HEAVY-DUTY GROW TENT USER MANUAL
WELCOME Thank you for choosing AC Infinity. We are committed to product quality and friendly customer service. If you have any questions or suggestions, please don’t hesitate to contact us. Visit www.acinfinity.com and click contact for our contact information. EMAIL WEB LOCATION support@acinfinity.com www.acinfinity.
MANUAL CODE CL2010X1 4 PRODUCT MODEL UPC-A CLOUDLAB 422 CLOUDLAB 632 CLOUDLAB 642 CLOUDLAB 733 CLOUDLAB 844 CLOUDLAB 866 AC-CBA422 AC-CBA632 AC-CBA642 AC-CBA733 AC-CBA844 AC-CBA866 819137021532 819137021556 819137021549 819137021563 819137021570 819137021587
MANUAL INDEX Manual Index ................................................................................. Page 5 Key Features ................................................................................. Page 6 Product Contents ........................................................................... Page 7 Tent Set Up .................................................................................... Page 9 Mounting Guide ...........................................................................
KEY FEATURES VIEWING WINDOW CONTROLLER PLATE Mylar canvas with 2000D density rating to be 100% external lightproof. Diamond-patterned interior lining amplifies reflectivity. Clear and adjustable window offers you a snapshot of the interior without compromising your environment. Aluminum plate designed to mount fan and lighting controllers. Their cords can enter the tent securely through the plate’s opening.
PRODUCT CONTENTS CLOUDLAB SERIES Included in all series CANVAS TENT (x1) STORAGE BAG (x1) SPILL TRAY (x1) FILTER STRAPS (x2) CONTROLLER SCREWS (x10) CLOUDLAB SERIES Included only with CLOUDLAB 844 CLOUDLAB 866 CONTROLLER VELCRO (x6) A B C AC-CBA844 AC-CBA866 INNER FLAP VELCRO (x2) E F D CONTROLLER PLATE (x1) x8 x4 x4 x8 x1 x2 FRAME POLES 7
PRODUCT CONTENTS CLOUDLAB SERIES Included only with CLOUDLAB 422 CLOUDLAB 733 A C F E AC-CBA422 AC-CBA733 D CONTROLLER PLATE (*SHORT) (x1) CLOUDLAB SERIES Included only with CLOUDLAB 632 B x8 x4 x4 x8 x1 x1 FRAME POLES A1 A2 B C E F AC-CBA632 D CONTROLLER PLATE (*SHORT) (x1) CLOUDLAB SERIES Included only with CLOUDLAB 642 x4 x4 x4 x4 x8 x1 x1 FRAME POLES A1 A2 B C E AC-CBA642 F D CONTROLLER PLATE (x1) 8 x4 x4 x4 x4 x8 x1 FRAME POLES x2
TENT SETUP X2 STEP 1 Insert the eight (A) poles into the floor end of the corner (D) pieces to create two bases. When assembling, make sure the feet of each corner (D) piece faces the floor with the arrow facing down. D A / A1 A / A2 D A / A2 NOTE: The poles in models AC-CBA632 and AC-CBA642 are labeled A1 and A2. A / A1 D D STEP 2 Insert the four (B) poles into Base One. Insert the four (C) poles into Base Two.
TENT SETUP STEP 3 Unzip the tent so that three of the walls lay flat. Door Roof Bottom STEP 4 Guide Base One into the floor of the tent, making sure its corners meet the tent’s corners.
TENT SETUP Base Two STEP 5 Insert the poles of Base Two into the poles of Base One to complete the frame. *Two people is recommended for this portion of the tent assembly. Base One STEP 6 Pull the roof over the assembled frame. *Two people is recommended for this portion of the tent assembly.
TENT SETUP STEP 7 Pull the upper and lower zippers to close the walls and door. *Two people is recommended for this portion of the tent assembly. STEP 8 You can neatly hold the window wall open any time by using its attached Velcro strap.
TENT SETUP STEP 9 Add the roof support beams (E) then (F). Insert the spill pool into the tent and secure the Velcro straps around the poles. E F E F F STEP 10 Mount your controller onto the included bracket. Use the included screws to mount an AC Infinity controller. Use the Velcro adhesive to attach a non-AC Infinity controller. Refer to page 15 for mounting locations of your controller.
TENT SETUP STEP 11 Slide the controller bracket assembly into the tent straps below the logo. STEP 12 Route your inline duct fan’s power connector through the opening inside and plug it into your controller. Plug the probe into the controller and route its cables through the opening.
MOUNTING GUIDE CONTROLLER PLATE This grow tent includes an aluminum bracket with mounting holes bored for AC Infinity controllers. Mount your controller to the corresponding holes on the bracket. Route its wires through the oval opening and through the grow tent’s flap. To attach non-AC Infinity controllers, use the included Velcro adhesive to hold it onto the bracket.
VENTILATION GUIDE INLINE FAN AND GROW LIGHT First hang your inline duct fan by the roof support beams. Position the fan on the opposite end of your intake hole to optimize airflow. If you are installing a carbon filter inside, use the included straps to hang the carbon filter. Then install your grow light. You may use rope clip hangers to install these products. DOUBLE-SIDED CINCHES Install any necessary duct tubes onto the ducting ports.
AC INFINITY PRODUCTS Inline Fans The CLOUDLINE series is a line of duct fans designed to quietly ventilate AV rooms and closets, as well as various DIY air circulation and exhaust projects. Features a thermal controller with intelligent programming that will automatically adjust duct fan speeds in response to changing temperatures. Carbon Filter The duct carbon filter is designed to eliminate odors and chemicals for grow tents and hydroponic spaces.
WARRANTY This warranty program is our commitment to you, the product sold by AC Infinity will be free from defects in manufacturing for a period of two years from the date of purchase. If a product is found to have a defect in material or workmanship, we will take the appropriate actions defined in this warranty to resolve any issues. The warranty program applies to any order, purchase, receipt, or use of any products sold by AC Infinity or our authorized dealerships.
COPYRIGHT © 2020 AC INFINITY INC. ALL RIGHTS RESERVED No part of the materials including graphics or logos available in this booklet may be copied, photocopied, reproduced, translated or reduced to any electronic medium or machine readable form, in whole or in part, without specific permission from AC Infinity Inc.
www.acinfinity.