60W Security Twinspot 754HB2/180/60 180° Outdoor Motion Sensor ® Installation Instructions Please leave these instructions at the installation site.
754HB2/180/60 60W Security Twinspot Installation Instructions Contents 1.0 Introduction............................................................................................... 3 1.1 Features............................................................................................. 3 1.2 Wireless Alarm Upgrade Kit............................................................... 4 2.0 Installation Procedure.............................................................................. 5 2.
754HB2/180/60 60W Security Twinspot Installation Instructions 1.0 Introduction Thank you for purchasing the 754HB2/180/60 Outdoor Infrascan Motion Detector. The Motion Detector unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the spotlights will illuminate for a user-determined time period. An integrated daylight sensor ensures nightonly operation.
754HB2/180/60 60W Security Twinspot Installation Instructions 1.2 Wireless Alarm Upgrade Kit Did you know that a Wireless RF Accessory Kit (754RFKIT) is available for this unit? The upgrade kit is battery powered and retro-fittable - no extra wiring is required. Simply plug in the external RF Transmitter to the floodlight and the portable Chime Receiver will alert you to any external activation of the floodlight.
754HB2/180/60 60W Security Twinspot Installation Instructions 2.0 Installation Procedure Unit is for outdoor use only. Unit must be mounted on a non-flammable surface as a fixed luminaire, and is not suitable for portable use. The unit can get very hot during use. Ensure the unit has cooled before handling. Ensure adequate ventilation space is allowed between the unit and any object above, in front or to either side of the unit. Suggested space is 0.5m above, 0.3m to either side and 1.0m in front.
754HB2/180/60 60W Security Twinspot Installation Instructions 2.2 Mounting the Unit 1. Remove the wall plate from the unit by inserting a terminal screwdriver into the slot at the top (see Diagram D). 2. Mark the position of the fitting holes. Drill the holes. Insert wallplugs into the holes. 3. BEFORE SECURING THE WALLPLATE TO THE WALL, PIERCE AND PASS THE CABLE THROUGH THE GROMMET. 4. Attach the wall plate to the wall (see Diagram E). 2.3 Electrical Connections 1.
54HB2/180/60 60W Security Twinspot Installation Instructions 2.4 Halogen Lamp Replacement - Caution Replacement lamp type is 240V 60W G9 mains halogen lamp. 1. Isolate the mains supply. 2. Unscrew the glass cover on the lamp housing. 3. To remove existing lamp, carefully pull lamp from socket. 4. Install new lamp, making sure not to touch the lamp with bare hands. It is suggested that the lamp is handled using a dry cloth. Push firmly to ensure that the lamp is properly seated in the lampholder. 5.
754HB2/180/60 60W Security Twinspot Installation Instructions 3.0 Commissioning Procedure 3.1 Walk Testing Procedure 1. The sensor will rotate from left to right. Adjust the sensor to point in the desired direction (see Diagram A and H for the different sensor patterns and lens masking). 2.
754HB2/180/60 60W Security Twinspot Installation Instructions 3.2 Adjustment Knobs PIR TIMER If the unit is set to AUTOMATIC MODE, the PIR TIMER setting controls how long the unit remains illuminated after motion has been detected (and after all motion has ceased). The minimum time (fully anti-clockwise) is approximately 5 seconds, whilst the maximum time (fully clockwise) is approximately 5 minutes. Set the control to the desired setting between these limits.
754HB2/180/60 60W Security Twinspot Installation Instructions 3.3 Setting up for Automatic Operation 1. When walk tests are complete, the unit can be switched to automatic operation. 2. The PIR TIMER setting controls how long the unit remains illuminated following activation and after all motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum time (fully clockwise) is approximately five minutes. Set the control to the desired setting between these limits. 3.
754HB2/180/60 60W Security Twinspot Installation Instructions 3.5 Special Functions MANUAL OVERRIDE MODE The light can be switched on for longer time periods by use of the MANUAL OVERRIDE MODE. The light can be activated AT NIGHT by using the internal wall switch / circuit breaker. Switch the internal wall switch / circuit breaker OFF/ON within 2 seconds.
754HB2/180/60 60W Security Twinspot Installation Instructions 4.0 Detection Range / Setting Controls A B TOP VIEW Less Sensitive 180° SIDE VIEW More Sensitive 2.
754HB2/180/60 60W Security Twinspot Installation Instructions 5.
754HB2/180/60 60W Security Twinspot Installation Instructions 6.0 Connection Diagram F Wall Plate Cable Entry Neutral Blue/Black (N) Earth Green/Yellow (E or ) Active/Live Brown/Red (L) Connect the mains cable to N,E and L connections in the terminal block. Match the three pins on the unit to the wall plate.
754HB2/180/60 60W Security Twinspot Installation Instructions 7.0 Angle Adjustment G The individual spotlights can be adjusted to angle the beam to cover the required area. The beam angle can also be adjusted by turning the back of the spotlight clockwise/anti-clockwise to change the beam pattern. 45° 45° 55° CAUTION IF THE PROTECTIVE GLASS SHIELD FOR THE LIGHT IS DAMAGED OR CRACKED IT MUST BE REPLACED IMMEDIATELY. 8.
754HB2/180/60 60W Security Twinspot Installation Instructions 9.0 Troubleshooting PROBLEM SOLUTION Lamp stays ON all the time at night. The unit may be suffering from false activation. Cover the sensor lens completely with a thick cloth. This will prevent the sensor from “seeing” anything. If the unit now switches off after the set time duration and does not re-activate, this indicates that the problem was caused by false activation. PIR keeps activating for no reason / at random.
754HB2/180/60 60W Security Twinspot Installation Instructions 10.0 Technical Specifications Operating Voltage 240V~ 50Hz a.c.
754HB2/180/60 60W Security Twinspot Installation Instructions 11.0 Warranty 1. The benefits conferred herein are in addition to, and in no way shall be deemed to derogate; either expressly or by implication, any or all other rights and remedies in respect to the Clipsal Product, which the consumer has under the Commonwealth Trade Practices Act or any other similar State or Territory Laws. 2. The warrantor is Clipsal Australia Pty Ltd of 33 - 37 Port Wakefield Road, Gepps Cross, South Australia 5094.
754HB2/180/60 60W Security Twinspot Installation Instructions 13.
754HB2/180/60 60W Security Twinspot Installation Instructions 14.