Use Instructions

14.1.2020 Rev.1
PLK/A1
Instructions for use
An ASSA ABLOY Group brand
Color Basic purpose
GREEN Indicates success
RED Indicates failure
WHITE Awake and not connected
BLUE Awake and connected
Function Color Indication
Wakeup, not connected WHITE Lit for 1 second
Wakeup, connected BLUE Lit for 1 second
Awake, not connected WHITE Blinking with 50ms on 950ms off cycle
Awake, connected BLUE Blinking with 50ms on 950ms off cycle
Battery poor RED Additional blink for 50ms after awake indication
Motor drive success (access granted) GREEN Lit for 2 seconds
Motor drive fail (access granted) RED Lit for 2 seconds
Going to sleep WHITE Blinking with 50ms on 150ms off for 1 second
The specs
Certications
Lock and unlock the
padlock a couple of
times so the rmware
checks the new battery
status.
2,5 mm
LED indiations
Changing the battery
123
4 5
Shackle diameter: 10 mm
Security grading: EN 16864:2017 11440D34
classication
Battery types:
For cold environment: Panasonic CR2
For warm environment: Saft LS14250 (use adapter)
CAUTION Risk of explosion if the battery is replaced by
an incorrect type
Battery life: 5 years / 5000 openings
O
perating temperature: -25 +60
Compatibility: Android devices with BT 4.0 and Android
version 4.4 or newer
The USB-C port is for service use only. If the battery is
completely discharged, use the USB power bank
(5Vdc 500mA) as backup power.
x2
3 mm
FCC ID: 2AI5J-PLKA1

Summary of content (2 pages)