Tropos Networks MetroMesh Router Installation Guide Model 5320 Tropos Networks, Inc. 555 Del Rey Ave. Sunnyvale, CA 94085 USA Part No.
Copyright Notice ©2006 Tropos Networks, Inc. All rights reserved. Tropos Networks is a registered trademark of Tropos Networks, Inc. in the United States and certain other jurisdictions. Specifications are subject to change without notice. Loctite is a registered trademark of Loctite Corporation, USA. This product includes technology protected by U.S. Patents 6,704,301; 6,965,575; 7,016,328, and 7,031,293. FCC Notice to Users and Operators This device complies with Part 15 of the FCC Rules.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des réglements d’équipement. L’opération est sujette aux deux conditions suivantes : (1) cet dispositif peut ne pas causer l'interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l'interférence qui peut causer l’opération peu désirée. Warning It is illegal to modify the construction of this product.
European Community Language Versions of Informal Statement for Inclusion in User Information The following statements are in accordance with Article 6.3 of Directive 1999/5/EC.
STOP!! STOP!! STOP!! STOP!! READ THIS FIRST! Important Safety Instructions The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
Warning Risk of personal injury or death when installing this device! There is a risk of personal injury or death if the router antennas come near electric power lines. Carefully read and follow all instructions in this manual. By nature of the installation, you may be exposed to hazardous environments and high voltage. Use caution when installing the outdoor system. This apparatus must be connected to earth ground. Do not open the unit — risk of electric shock inside. Risque d'électrocution.
The Tropos 5320 MetroMesh Router is installed in wet, outdoor locations. Make sure closure caps are installed and all cable connections are securely fastened and waterproofed. The Tropos 5320 MetroMesh Router can only be used with approved antennas. See Appendix C, “Approved Antenna Configurations and Attenuation Settings” for further information. Surfaces may become hot. Use caution when accessing the Tropos 5320 MetroMesh router.
Contents 1 Installing the Tropos MetroMesh Router . . . . . . . . . . . . . . . . . . . . . . . . . 1 Preparing for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Model Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation Hardware and Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Site Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 3 Product Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 4 Approved Antenna Configurations and Attenuation Settings . . . . . . . 48 High Power Product Antennas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . U.S. and Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard Power Product Antennas .
List of Figures Tropos MetroMesh Router Exploded View . . . . . . . . . . . . . . . . . . . . . . . 3 Example Mounting Location - Antennas Facing Upward . . . . . . . . . . . . 7 Proper Use of Hose Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Metal Pole Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Sun Shield Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Wood Pole Mounting . . . . . . . . .
List of Tables IEEE/ANSI C62.41 Power Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PoE Power Sourcing Power Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RJ45 Pin Descriptions for Data Connection . . . . . . . . . . . . . . . . . . . . . . . . Physical Specifications - Tropos 5320 Router . . . . . . . . . . . . . . . . . . . . . . . Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 Installing the Tropos MetroMesh Router This guide explains how to install the Tropos 5320 MetroMesh router safely and is intended for trained technical professionals.
Preparing for Installation Preparing for Installation The Tropos 5320 MetroMesh router must be installed by a trained professional, value added reseller, or systems integrator who is familiar with RF planning issues and regulatory limits defined by the governing body of the country in which the unit will be installed. This section lists the required equipment and model numbers and explains how to prepare the installation site.
Preparing for Installation Figure 1 Tropos MetroMesh Router Exploded View 802.11b/g Aux Tx/Rx antenna 802.11a 802.
Preparing for Installation Installation Hardware and Tools Tropos Networks provides the following accessories to install the Tropos 5320 MetroMesh router: One pole bracket One sun shield Two 4-inch diameter hose clamps Four 6-inch diameter hose clamps Seven 5/16-inch #10-32 stainless steel hex head machine screws You must supply the following tools: 5/16-inch nut driver 1/4-inch flat blade screwdriver Tower mounting only: supply stainless or galvanized steel channel stock and 1/2-inch
Preparing for Installation a UL497A (UL/CSA/TUV Listed) secondary protection device at the building entrance. Tropos Data Protection Device and Network Protection Units are UL497A secondary protection devices. Location Guidelines The Tropos 5320 MetroMesh router is a radio device and therefore susceptible to interference that can reduce throughput and range.
Preparing for Installation Antenna type and placement—Proper antenna configuration is a critical factor in maximizing radio range. As a general rule, range increases in proportion to gain and antenna height measured from the ground. Physical environment—Clear or open areas provide better radio range than closed or filled areas. The less cluttered the operating environment, the greater the range.
Mounting Strategies Contact with AC wiring Mounting Strategies When choosing mounting locations, consider the available mounting structures and antenna clearance. The Tropos 5320 MetroMesh router should always be mounted with the top of the unit horizontal and level and with the antennas facing upward. It is usually best to attach ground and data cables to the router prior to mounting.
Proper Use of Hose Clamps Proper Use of Hose Clamps The mounting assembly for the Tropos 5320 MetroMesh router contains hose clamps to secure the router to the mounting structure. Figure 3 illustrates the proper use of the hose clamps. The clamps must be routed through slots in the pole bracket as shown in the figure, and then attached to the pole and tightened.
Pole, Tower, and Streetlight Mounting Instructions Pole, Tower, and Streetlight Mounting Instructions This section explains how to mount the Tropos 5320 MetroMesh router on a pole, tower, or streetlight. It is best to mount the router to aluminum or galvanized steel structures. The mounting brackets are designed to pierce any oxidation layers that are on the outside of the pole, thereby assuring good quality connection to the grounded structure.
Pole, Tower, and Streetlight Mounting Instructions Metal Pole Mounting Figure 4 illustrates the proper method of mounting the Tropos 5320 MetroMesh router on an outdoor metal pole. Note Antennas must be clear of obstruction.
Pole, Tower, and Streetlight Mounting Instructions Mount the Tropos 5320 MetroMesh router on a metal pole 1. Select a mounting location. You can attach the router to any pipe or pole with diameter between 1 inch and 10 inches. 2. Slip the flat portion of the hose clamps under the inner tabs or slots of the pole bracket. 3. Use the hose clamps to attach the pole bracket to the pole.
Pole, Tower, and Streetlight Mounting Instructions Figure 5 Sun Shield Connections Screws to attach router to sun shield Bubble level Use lag bolts to attach sun shield to wooden pole Use machine screws to attach sun shield to pole bracket trp_154 Tropos 5320 MetroMesh Router Installation Guide 12
Pole, Tower, and Streetlight Mounting Instructions Wood Pole Mounting Figure 6 shows a typical installation with the Tropos 5320 MetroMesh router mounted on an outdoor wood pole. Note Antennas must be clear of obstruction.
Pole, Tower, and Streetlight Mounting Instructions Mount the Tropos 5320 MetroMesh router on a wood pole 1. Select a mounting location. You can attach the router to any outdoor wood pole of diameter at least 1 inch. 2. Attach the sun shield of the router to the pole with two 5/8-inch bolts, making sure that the shield is level. Figure 5 on page 12 shows the proper bolt locations on the back of the sun shield. The bolts should be at least 3 inches in length. 3.
Pole, Tower, and Streetlight Mounting Instructions Mount the Tropos 5320 MetroMesh router on a wood pole 1. Select a mounting location. You can attach the router to any wood brace. 2. Attach the pole bracket to the wood brace with two 1/4-inch lag bolts that are at least 2 1/2 inches in length, making sure that the wood brace is level. 3. Attach the sun shield of the router to the pole bracket with three 5/16-inch machine screws.
Pole, Tower, and Streetlight Mounting Instructions Tower Mounting You can mount the Tropos 5320 MetroMesh router to an outdoor tower. Note At the antenna level, the Tropos 5320 MetroMesh router must be free from metal obstruction within a 4-foot radius (Figure 8). Figure 8 Tower Mounting 4' Channel stock Brackets not included trp_156 Mount the Tropos 5320 MetroMesh router on a tower 1. Remove the pole bracket from the sun shield. 2.
Pole, Tower, and Streetlight Mounting Instructions Streetlight Mounting You can mount the Tropos 5320 MetroMesh router on the horizontal or angled arm of a streetlight. Figure 9 shows a typical streetlight mounting installation. Figure 9 Streetlight Mounting Pole bracket Sun shield Router trp_157 Mount the Tropos 5320 MetroMesh router on a streetlight 1. Select a mounting location. You can attach the router to any streetlight arm with diameter 1” to 10”. 2.
Connecting Cable Attached Antennas 4. Attach the sun shield of the router to the structure with three 5/16-inch machine screws. Insert one screw through the hole in the center back of the sun shield and the other two screws through the curved slot tracks. 5. To level the assembly, slide the router loosely into the sun shield, but do not secure it. Level the sun shield by rotating the unit along the curved slot tracks. A built-in level is located on the left side of the shield.
Connecting Cable Attached Antennas Figure 10 Connecting External Antennas Cables from antennas to unit 802.11a antenna 802.11b/g Main antenna 802.11b/g Aux antenna trp_101 trp_158 Connect antenna cables 1. Mount the antennas in a suitable location, following the instructions supplied with the antennas. 2. Perform a trial installation of the antenna cables. 3.
Connecting Cable Attached Antennas Waterproofing Antenna Connections Figure 11 illustrates how to waterproof the antenna connections after they are installed. Make sure that you waterproof the connections at both ends (cable-to-antenna and cable-to-router). Waterproof the antenna connections 1. Locate the self-fusing EPR waterproofing tape included in the antenna installation kit. 2. Separate the liner from the tape. 3. Pre-stretch the tape and wrap it tightly around the connector.
Grounding the Tropos 5320 Router Installing Attached Antennas The following steps explain how to install antennas that are attached directly to the Tropos 5320 MetroMesh router. Replace the Tropos 5320 MetroMesh router antennas 1. Turn power off to the router. 2. Remove the screws that secure the router to the sun shield, and slide the router out from the sun shield. 3. Apply two drops of Loctite Threadlocker 242 to the antenna connector thread. 4.
Grounding the Tropos 5320 Router Figure 12 Grounding Arrangement Grounding screw Grounding strap on pipe or grounding rod 10 AWG wire to ground trp_104 Ground the Tropos 5320 MetroMesh router 1. Insert the grounding screw into the grounding screw hole on the bottom of the router. 2. Connect a length of #10 AWG bare copper wire to the grounding screw and tighten. 3.
Grounding the Tropos 5320 Router Grounding the Data Protection Device The grounding arrangement for an indoor data protection device is shown in Figure 13. Ground an indoor data protection device 1. Place the protection device as close to the building entrance as possible. 2. Connect a length of #10 AWG bare copper wire to the ground post on the data protection device. 3. Connect the other end of the grounding wire to the ground connection of an electrical outlet or a grounded water pipe.
Connecting Power Connecting Power This section explains the different categories of electrical power and provides procedures for connecting the outdoor system to power.
Connecting Power Table 1 IEEE/ANSI C62.
Connecting Power Figure 14 IEEE/ANSI C62.
Connecting Power Connecting to AC Power (Category C) The AC power connections for a Category C AC power source are shown in Figure 15. Figure 15 Connecting Category C AC Power AC wiring in junction box Wire nuts Green wire White wire Black wire To outdoor unit AC power from meter To power source trp_106 Connect an AC power source 1. Verify that the service voltage is 100-480 VAC 50/60 Hz. 2. Verify that power is turned off on the designated circuits. 3.
Connecting Power Note The Tropos 5320 MetroMesh router is equipped with additional AC surge protection and dual fuse branch circuit protection. Additional ISA branch circuit protection is not required in the upstream power distribution. Figure 16 Connecting the AC Power Cable Tighten nut to secure power connection trp_107 Connecting to Streetlight Power (Category C) The power connections for Category C streetlight power are shown in Figure 17.
Connecting a Data Port Warning Connect the outdoor system only to a twist-lock style outdoor lighting control powered by 100-480 VAC 50/60 Hz. Do not connect it to twist-lock style outdoor lighting controls powered by higher voltage. Connect a streetlight power source 1. Verify that the service voltage is 100-480 VAC 50/60 Hz. 2. Verify that power is turned off on the designated circuits. 3. Remove the photosensor from the streetlight. 4.
Connecting a Data Port Note Only use shielded Cat5 cable rated for outdoor use. For protection against risk of fire, electrical hazard and to ensure the reliable operation of this equipment, the shields of the Cat5 cable must be properly terminated and bonded to the unit and to the protective earth (PE) at the building entrance.
Connecting a Data Port Figure 18 illustrates the method for routing cables to the Tropos 5320 MetroMesh router. Use the RJ45 jacks for port connection.
Connecting a Data Port Figure 19 shows the layered shield and jacket for the data cable, which must be removed to expose the inner cable and twisted pairs. Figure 19 Data Cable Detail Watertight bulkhead cable glands Cable Belfoil shield Connector access cover Terminate cable shield at cable gland 1/2 inch Outer jacket Twisted pairs Conductive shield Securely tighten gland for weathertight seal trp_117 Note Attach ground and data cables to the router before sliding it into the sun shield.
Connecting a Data Port Figure 20 Data Port Connection AC power connector Connector access cover Ground bolt Cable guides O-ring Tighten six screws to fasten bulkhead plate trp_112 6. Connect the cable ends that were routed through the connector access cover to the LAN and Management ports on the router. Use an appropriate RJ45 8-pin modular plug to terminate the cables at the desired lengths.
Resetting the Router Figure 21 Circuit Board Connection Locations Screw holes for access cover LAN punch-down block Management punch-down block LED Brown LED Reset Management LAN port port Threaded hole for grounding bolt AC power connector trp_110 Resetting the Router You can use the Reset button on the circuit board to reset the hardware and software and to turn the router off if it is operating on battery power. Perform a hardware reset 1.
Connecting Peripherals Connecting Peripherals The Tropos 5320 MetroMesh router can be configured to source DC power on the Ethernet connector pins 4,5 and 7,8, This capability allows the router to power remote peripherals such as backhaul point-to-point radios, video cameras, or fiber optic transceivers. The Tropos Power over Ethernet (PoE) power sourcing capability is a fully isolated supply and can be used to power either positive or negative polarity peripherals.
Connecting Peripherals Figure 22 shows the pin locations for the RJ45 connector, and Table 3 shows the associated pin descriptions.
Battery Backup Operation Battery Backup Operation The Tropos 5320 MetroMesh router may contain an automatically recharging battery, which provides an integrated uninterruptible power supply (UPS). The available backup time depends upon the level of network traffic serviced by the router and the ambient temperature. Figure 24 shows the relationship between average throughput and battery uptime. The Tropos 5320 router will typically recharge the UPS in approximately 10 hours.
Safety Information for the Tropos MetroMesh Router Figure 24 Average Battery Backup Time vs. Temperature Safety Information for the Tropos MetroMesh Router The Federal Communications Commission (FCC) with its action in ET Docket 96-8 has adopted a safety standard for human exposure to RF electromagnetic energy emitted by FCC certified equipment. The Tropos 5320 products meet the uncontrolled environmental limits found in OET-65 and ANSI C95.1, 1991.
Safety Information for the Tropos MetroMesh Router The use of wireless devices on airplanes is governed by the Federal Aviation Administration (FAA). The use of wireless devices in hospitals is restricted to the limits set forth by each hospital. Antenna use: The Tropos 5320 MetroMesh routers must be used only with Tropos-approved components and antennas. See “Approved Antenna Configurations and Attenuation Settings” on page 48 for details.
2 Power Consumption Several factors influence the power consumption at any given time, including the level of network traffic and whether a powered peripheral device is connected to the LAN or Management port of the Tropos 5320 MetroMesh Router. Temperature may also influence the power consumption for units configured with battery backup, due to the internal freeze protection capability associated with the internal battery module.
When a Tropos 5320 MetroMesh Router is equipped with a battery and the router is exposed to cold temperatures (below -12 degrees C), the internal heater associated with the battery is activated. This causes the router to draw additional AC power, as shown in Figure 26. Figure 26 AC Power Consumption vs.
3 Product Specifications The tables in this chapter contain specifications for the Tropos 5320 MetroMesh routers: “Physical Specifications - Tropos 5320 Router” on page 42 “Interfaces” on page 44 “Power Options / Consumption” on page 46 “Power Over Ethernet - Power Sourcing” on page 47 “Certifications, Other” on page 47 Table 4 Physical Specifications - Tropos 5320 Router Physical Dimensions Height Width Depth Inches 5.3 13.2 7.9 Centimeters 13.5 33.5 20.
Table 4 Physical Specifications - Tropos 5320 Router (continued) Transportation: ISTA 2A Random Bounce Random Vibration 6 Corner Drop Test Reliability Reliability (MTBF): 505,787 hours demonstrated Field failure rate 1.
Table 5 Interfaces Data Interface IEEE 802.3 10/100BaseT Management Interface IEEE 802.3 10/100Base T Maximum Distance (ft) Connector 600 (10BaseT Duplex Setting) 300 (100BaseT Duplex Setting) RJ45 Maximum Distance (ft) Connector 600 (10BaseT Duplex Setting) 300 (100BaseT Duplex Setting) RJ45 802.11b/g Wireless Interface Standard IEEE 802.11b/g Wi-Fi Frequency Range Modulation 2400 to 2485 MHz ISM Band DSSS; DBPSK @ 1 Mbps, DQPSK @ 2 Mbps, CCK @ 5.
Table 5 Interfaces (continued) 802.11a Wireless Interface Standard IEEE 802.
Table 6 Power Options / Consumption Single Phase VAC 100-480 VAC 50/60 Hz IEEE/ANSI C62.41 CAT C Power Source IEC Category IV Power Source 23W/60W typical/max Protection Circuits Antenna Protection <= 0.5µJ for 3kA @ 8/20µS Waveform EN61000-4-2 Level 4 ESD Immunity EN61000-4-5 Level 4 Surge Immunity AC Input Protection IEEE/ANSI C62.
Table 7 Power Over Ethernet - Power Sourcing LAN and/or Management Port + on pins 4,5; - on pins 7,8 DC Output Voltages 0 (Off), 12, 24, 48 Vdc Output Power Total power on LAN and/or Management ports Voltage 12Vdc 24Vdc 48Vdc Over-Current Protection Hi Cup mode Over-Voltage Protection 90Vdc surge Output Isolation Max Power Output 30W 30W 30W 2000Vdc Table 8 Certifications, Other U.S. Europe CFR 47 FCC Part 15.
4 Approved Antenna Configurations and Attenuation Settings This chapter lists approved antenna configurations and ordering information and attenuation settings: “High Power Product Antennas” on page 49 “Standard Power Product Antennas” on page 50 Tropos 5320 MetroMesh Router Installation Guide 48
High Power Product Antennas High Power Product Antennas U.S. and Canada The information in this section applies to the following Tropos router models: 53201000—Dual mode outdoor Tropos router for FCC markets (802.11b/g and 802.11a, 5.8 GHz) 53201100—Dual mode outdoor Tropos router for FCC markets (802.11b/g and 802.11a, 5.8 GHz), with battery backup Table 9 lists antenna configurations for the 802.11b/g antennas, and Table 10 lists antenna configurations for the 802.11a antennas. Table 9 802.
Standard Power Product Antennas Table 10 802.11a Radio (5.725-5.850 GHz) - Antenna Configurations Part Number Measured Cond. Avg. Power (dBm) Tx Attenuation Software Setting (dB) Approximate EIRP (dBm) 9.1dBi omni, unit mounted, point-tomultipoint operation AN091058 26.9 0 36.0 17dBi 90° sector, external bracket mounted, point-to-point operationa AN170058 26.9 0 43.9 17dBi 90° sector, external bracket mounted, point-to-multipoint operationa AN170058 18.9 8 35.
Standard Power Product Antennas Malta, Netherlands, Norway, Poland, Portugal, Slovak Republic, Slovenia, Spain, Sweden, Switzerland, and the United Kingdom. The information in this section applies to the following Tropos router models: 53200000—Dual mode outdoor Tropos router for ETSI markets (802.11b/g and 802.11a, 5.4 GHz) 53200100—Dual mode outdoor Tropos router for ETSI markets (802.11b/g and 802.11a, 5.4 GHz), with battery backup Table 11 lists antenna configurations for the 802.
Standard Power Product Antennas a. All external antennas include pole mounting bracketry and sealing materials. RF cables are not included.
5 Antenna Specifications and Patterns Table 13 provides antenna specifications and patterns for the Tropos-supplied antennas.
Table 13 Antenna Specifications and Patterns Part Number AN060077 Specifications Pattern One outdoor 6.0dBi omni unit-mounted antenna; N connector • Length: 11.9 in (30.3 cm) • Weight: 4.4 oz (.125 kg) • Color: White • Measured peak gain: 5.
Table 13 Antenna Specifications and Patterns (continued) AN074077 AN074088 One outdoor 7.4dBi omni unit-mounted antenna; N connector • Length: 19 in (48.3 cm) • Weight: 4.7 oz (.133 kg) • Color: White • Measured peak gain: 7.1dBi • Connector type: N male One outdoor 7.4dBi omni mast-mounted antenna; N connector; bracketry • Length: 19 in (48.3 cm) • Weight: 4.7 oz (.133 kg) • Color: White • Measured peak gain: 7.
Table 13 Antenna Specifications and Patterns (continued) AN100022 One outdoor 9.9dBi omni mast-mounted antenna; N connector; bracketry • Length: 45 in (114.3 cm) • Weight: 20 oz (.57 kg) • Color: White • Measure peak gain: 9.
Table 13 Antenna Specifications and Patterns (continued) AN120022 One outdoor 12.0dBi 90° sector antenna; N connector; bracketry • Length: 34 in (86.4 cm) • Width: 3 in (7.6 cm) • Depth: 1.2 in (3.0cm) • Weight: 25.6 oz (.73 kg) • Color: Gray • Measured peak gain: 12.
Table 13 Antenna Specifications and Patterns (continued) AN120022 (continued) Outdoor 12.
Table 13 Antenna Specifications and Patterns (continued) AN091058 Outdoor 9.1dBi omni antenna; N connector • Length: 17.5 in (43.2 cm) • Weight: 4.7 oz (.133 kg) • Color: White • Measured peak gain: 6.
Table 13 Antenna Specifications and Patterns (continued) AN170058 Elevation Outdoor 17.0dBi 90° sector antenna; N connector, bracketry • Length: 14.5 in (370 cm) • Width: 6.7 in (170 cm) • Depth: 2.5 in (65 cm) • Weight: 2.2 lbs (1 kg) • Color: gray • Measured peak gain: 15.
Table 13 Antenna Specifications and Patterns (continued) AN190058 Elevation Outdoor 19.0dBi 16° patch antenna; N connector, bracketry • Length: 7.45 in (189 cm) • Width: 7.45 in (189 cm) • Depth: 1.37 in (35 cm) • Weight: 1.6 lbs (0.72 kg) • Color: gray • Measured peak gain: 17.
Table 13 Antenna Specifications and Patterns (continued) AN170054 Patterns not available One outdoor 17.0dBi 90° sector antenna; N connector; bracketry • Length: 14.5 in (370 cm) • Width: 6.7 in (170 cm) • Depth: 2.5 in (65 cm) • Weight: 2.2 lbs (1 kg) • Color: gray • Measured peak gain: • Connector Type: N Female AN190054 Patterns not available One outdoor 19.0dBi 16° patch antenna; N connector; bracketry • Length: 7.45 in (189 cm) • Width: 7.45 in (189 cm) • Depth: 1.37 in (35 cm) • Weight: 1.6 lbs (0.
6 Installation Accessories This chapter contains accessory ordering information: “Installation Accessories” on page 63 “Tropos Antennas, Cables, and Related Ordering Numbers” on page 64 Table 14 Installation Accessories Description Manufacturer Part Number Distributor Contact Information Outdoor CAT5 4-Pair Data Cable Belden 7929A Anixter www.anixter.com Belden 7921A (recommended) Anixter www.anixter.com Superior Essex BBDG Anixter www.anixter.
Table 14 Installation Accessories Description Manufacturer Part Number Yellow 3-Pin Mini-Link AC Plug Female Pig Tail Unterminated 12 ft. McMaster-Carr 321K16 Anti-seize lubricant Loctite 37230 Universal remote control Universal Remote MX-500 Distributor Contact Information Order Number www.mcmastercarr.com McMaster Carr www.mcmaster.com www.universalremote.com Table 15 Tropos Antennas, Cables, and Related Ordering Numbers Part Number Description AN060077 One outdoor 6.
Table 15 Tropos Antennas, Cables, and Related Ordering Numbers Part Number Description PT032030 5320 input power cable - pigtail, 3-wire, 30 ft.
7 AC Wiring Diagrams This chapter contains wiring diagrams for AC power: “AC Wiring — Photoelectric Power Tap” on page 67 “AC Wiring Power Cable 120VAC, 15A Plug” on page 68 Tropos 5320 MetroMesh Router Installation Guide 66
Figure 27 AC Wiring — Photoelectric Power Tap PT021004 (4') or PT021020 (20') Photoelectric Power-Tap Power Input Cable 2Wire - 90-480Vac Length: 4' or 20' NEMA Plug - UL Standard 773 Plug-in locking type for photocontrols in use with area lighting North 1 L2 / N White 3 2 1 - Green 2 - Black 3 - White 16/2 SOOW L1 Black Carol P-7K-123033 MSHA or equal Router Power-Tap single phase; two wire service Black L1 White North N North N Black L1 White L1 L2 Protective Earth NEMA Photoelectric Con
Figure 28 AC Wiring Power Cable 120VAC, 15A Plug PT031006 (6’) or PT031030 (30’) Overvoltage Category 2 or IEEE/ANSI C62.
8 Wind Loading Considerations The American Association of State Highway and Transportation Officials (AASHTO) standards manual, “Standard Specifications for Structural Supports for Signs, Luminaires and Traffic Signals,” governs most structural support issues related to traffic lighting and controls. Many state and city public works departments site the AASHTO standard as the guide for their requirements. Local municipalities in coastal states, which experience frequent hurricanes, etc.
9 Canopy Installation Instructions The 5320 Canopy Subscriber Module and Bracket kit allows you to attach a third-party radio, the Motorola Canopy Subscriber Module, to the Tropos 5320 MetroMesh Router. The kit includes the following items: Outdoor CAT5 weatherproof cable Bracket (metal pole) Screws #6-32 x 1.5" Lockwashers Cable ties Follow these steps to install the canopy (refer to Figure 29): 1. Align the bracket and attach it using the three screws included in the kit. 2.
Figure 29 Canopy Assembly Screws #6-32 x 1.5" Canopy bracket Lock washers Screws #6-32 x 1.
4. Unscrew the 6 screws around the Tropos 5320 access cover (Figure 30). Replace the access cover of the 5320 unit with the access cover provided with the Canopy Subscriber Module cable. 5. Connect cable to the LAN port inside the 5320 unit.
Figure 30 Cable Connections Watertight access cover cable glands Connector access cover LAN port Shield termination Tighten six screws to fasten access cover Management port Cable from radio Cable terminated with RJ45 jack for port connection Screw holes for access cover Cable ties Drip loop trp_122a 6. Attach the access cover by tightening the 6 screws. Check that the cable gland is securely tightened. 7. Secure the weatherproof cable to the canopy bracket with two cable ties (Figure 29).
Table 16 Canopy Cable Wiring Canopy SM (RJ45) Color Tropos 5320 MetroMesh Router Signal 3 Orange 1 TXD+ 6 Orange-White 2 TXD- 1 Blue 3 RXD+ 7 Green 4 24Vdc+ 8 Green-White 5 24Vdc+ 2 Blue-White 6 RXD- 4 Brown 7 24Vdc_RTN 5 Brown-White 8 24Vdc_RTN Shield Drain wire Tropos 5320 MetroMesh Router Installation Guide Shield Shield 74
10 Cable Termination Instructions Follow these steps to prepare and terminate cables connected to the 5320 unit: 1. Strip off the outer sheath of cable to expose 6 inches of the inner cable or twisted pairs. The shield may be armored, braided or foil type depending upon cable type (see Table 31). 2. For armored or braided cable, remove all but 1/2 inch of the armor or braid. Remove waxy residues on the shields of “flooded” type cables.
3. Run the stripped part of the cable through the cable gland (Figure 32). Make sure that the braided conductive shield of the cable makes contact with the conductive contacts of the cable gland (Figure 32). 4. Attach the cable gland by first tightening the gland base into the access cover. Then tighten the gland cover to constrict the weather-tight grommet around the outer jacket of the cable, thereby creating a weather-tight fitting.
Table 17 TIA/EIA 5688 Wiring - RJ-45 Pin Descriptions for Data Connection Pin T/R Signal Color 1 T TXD+ Orange-White TX Data 10/100BaseT 2 R TXD- Orange TX Data 10/100BaseT 3 T RXD+ Green-White RX Data 10/100BaseT 4 R PoE+ Blue Power output, 0, 12, 24, 48 Vdc (+) 5 T PoE+ Blue-White Power output, 0, 12, 24, 48 Vdc (+) 6 R RXD- Green RX Data 10/100BaseT 7 T PoE- Brown-White Power output, 0, 12, 24, 48 Vdc (-) 8 R PoE- Brown Power output, 0, 12, 24, 48 Vdc (-) Tropo
Abbreviations The following acronyms are used in this document.
Table 18 Acronyms (continued) DGT Directorate General of Telecommunications (Taiwan) DQPSK Differential-Quadrature Phase-Shift Keying DSSS Direct-Sequence Spread Spectrum EFT Electrically Fast Transients EIRP Effective Isotropic Radiated Power EMC Electromagnetic Compatibility EN IEC standard ESD Electrostatic Discharge ETSI European Telecommunications Standards Institute FCC Federal Communications Commission FHSS Frequency Hopping Spread Spectrum HFC Hybrid Fiber Coax Hz Hertz IEC
Table 18 Acronyms (continued) NEMA National Electrical Manufacturers Association OFDM Orthogonal Frequency Division Multiplexing P Phase PE Protective Earth PoE Power over Ethernet RJ45 Registered Jack 45 RSS Received Signal Strength Rx Receive RXD Receive Data TUV Technical Inspection Association Tx Transmit TXD Transmit Data UL Underwriters Laboratories UPS Uninterruptible Power Supply VAC Voltage (Alternating Current) VCCI Voluntary Control Council for Interference (Japan)
Index power 24 connecting a data port 29 connecting data ports 32 connecting peripherals 35 D A AC power source 6 wiring diagrams 66 American Association of State Highway and Transportation Officials (AASHTO) 69 antenna type and placement 5 antennas approved configurations 48 connecting 18 distances from people 5 external 19 omni-directional 5 options 5 waterproofing 20 attenuation 50 B battery backup 37 turning router off 34 battery backup vs.
site surveys 5 specifications 42 streetlight mounting instructions 17 mounting options 7 power 28 sun shield 12 T terminating cables 75 tools for installation 4 tower mounting 16 V voltage 6 W warnings, general vi waterproofing antenna connections 20 wind loading 69 wiring diagrams 66 wood brace mounting 14 wood pole mounting 13 Tropos 5320 MetroMesh Router Installation Guide