ID User Manual Doc No. : TM- 501 EN Rev 0.1.8 July. 2013 Part No. : CR-FPM-54-001 3DISC, Fire ID, Quantor and the 3D Cube are trademarks of 3D Imaging & Simulations Corp, South Korea, and its affiliates. All other trademarks are held by their respective owners and are used in an editorial fashion with no intention of infringement. The data in this publication are for illustration purposes only and do not necessarily represent standards or specifications, which must be met by 3D Imaging & Simulations Corp.
User Manual Fire ID TM-801-EN Contact 815, Tamnip-Dong, Yuseong-Gu, Daejeon, Korea Tel : 82-42-931-2100 Fax : 82-42-931-2299 Website : www.3DISCimaging.com E-mail : info@3DISCimaging.com 3DISC Americas 22560 Glenn Dr, Suite 116 Sterling, VA 20164 USA Tel : 1-703-430-6080 E-mail : info@3DISCimaging.com 3DISC Europe Gydevang, 39-41, 3450 Alleroed, Denmark Tel : 45-88-276-650 E-mail : info@3DISCimaging.
User Manual Fire ID TM-801-EN The device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. NOTE : This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
User Manual Fire ID TM-801-EN Warnings and Used Symbols To ensure the safety of patients, staff and other persons, any changes to software and hardware delivered by 3D Imaging & Simulations Corp. may only be made with prior written permission from 3D Imaging & Simulations Corp. The following symbols will be used throughout this manual: DANGER This equipment is indoor use only and all the communication wirings are limited to inside of the building.
User Manual Fire ID TM-801-EN General Safety Guidelines This device has been designed and tested to meet strict safety requirements applicable to IT equipment, and has been supplied in a safe condition. 3D Imaging & Simulations Corp. assumes no liability for failure to comply. If this device is not used as specified, the protection provided by the device could be impaired. This device must be used in a normal condition only. There are no user serviceable parts inside this device.
User Manual Fire ID TM-801-EN Index of contents Chapter 1. Introduction ..................................................................... 8 Chapter 2. Unpacking ....................................................................... 9 2.1. 2.2. Inspection for Damage ..................................................................... 9 Identify the Components ................................................................... 9 Chapter 3. Setting Up .................................................
User Manual Fire ID TM-801-EN Chapter 7. Technical Assistance .....................................................
User Manual Fire ID TM-801-EN Chapter 1. Introduction Compact & Affordable The Fire ID is compact and affordable, helping to increase patient throughput and improve the overall productivity of your practice. With its small footprint, the reader fits seamlessly into even the most space-challenged clinic and exam rooms. Elegant Design & Streamlined Operation The Fire ID’s elegant design belies a powerful yet easy-to-use system that gets the job done day in and day out.
User Manual Fire ID TM-801-EN Chapter 2. Unpacking 2.1. Inspection for Damage Fire ID is shipped in a custom designed box to protect the reader from external shock. Before unpacking the reader, inspect the shipping box for damage. In case the box is damaged, notify the shipper immediately. 2.2. Identify the Components Open the shipping container and identify each of these components. Part No.
User Manual Fire ID TM-801-EN Chapter 3. Setting Up WARNING Unsuitable Installation Sites Locations with excessive humidity or dust Locations subject to high temperature Locations subject to shaking or vibration Locations exposed to considerable electrical or magnetic noise, or other forms of electromagnetic energy Locations with poor heat radiation 3.1 Identify Important Features Look over the Fire ID and features shown in this section.
User Manual Fire ID TM-801-EN 3.2. Computer Requirements 3.2.1. Recommended Requirement Operation System Microsoft Windows 7 (32 bit or 64 bit) CPU Core Duo / Core2 Processor Memory RAM 4GB or more Hard Disk 300GB Free Hard Disk Space Network 1Gbps Ethernet Video 32 bit Color Display Video Resolution 1280 x 1024 3.2.2.
User Manual Fire ID TM-801-EN Figure 4. USB Connection DANGER This equipment is indoor use only and all the communication wirings are limited to inside of the building. WARNING Do not pull out the USB cable during tag information reading. 3.3.2. Installation Report After installation of the reader, fill in Installation Report from (Appendix I) and send to 3D Imaging & Simulations Corp. service department by fax or e-mail. Fax : +82-42-931-2299 E-mail : support@3DISCimaging.
User Manual Fire ID TM-801-EN Chapter 4. Operating 4.1. System Specifications Dimension 27 x 60 x 96 (H x L x W) Weight 90g Frequency 13.56MHz Protocol ISO 15693 Interface Mini USB B Power Supply USB Power Temperature Range -25℃ to +70℃ * Specifications subject to change without notice. WARNING There are no user serviceable parts inside the reader. The reader should only be opened and serviced by qualified service personnel.
User Manual Fire ID TM-801-EN 4.2. Operating Specifications 4.2.1. Circuit Functions Figure 8. Circuit Diagram 9 Linear Regulator: PC receives power from +3.
User Manual Fire ID TM-801-EN Chapter 5.
User Manual Fire ID FCC ID : X68CRSCANNER4 TM-801-EN FCC Mark Medical Equipment WITH RESPECT TO ELECTRIC SHOCK FIRE, AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL60601-1 / CAN / CSA CSS.2 No. 601.
User Manual Fire ID TM-801-EN 5.1. Manufacturer’s Declaration- Electromagnetic Emission The Fire ID system is intended for use in the electromagnetic environment specified below. The customer or the user of Fire ID system should assure that it is used in such an environment Emission test RF emissions CISPR 11 Compliance Group 1 Class B Electromagnetic environment - guidance The Fire ID system uses RF energy only for its internal function. Therefore.
User Manual Fire ID Radiated RF IEC 61000-4-3 TM-801-EN 3 V/m 80.0 MHz to 2.5 GHz 3 V/m 80.0 MHz to 2.5 GHz Recommended separation distance Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as deter-mined by an electromagnetic site survey, (a) Should be less than the compliance level in each frequency range (b).
User Manual Fire ID TM-801-EN power (W) of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz 0.01 0.12 0.12 0.23 0.1 0.37 0.37 0.74 1 1.17 1.17 2.33 10 3.70 3.70 7.37 100 11.70 11.70 23.
User Manual Fire ID TM-801-EN 5.3. Guidance and Manufacturer ’s Declaration – Electromagnetic Immunity The Fire ID system is intended for use in the electromagnetic environment specified below.
User Manual Fire ID TM-801-EN Chapter 6. Warranty and Repair Service 6.1. Standard Warranty 3D Imaging & Simulations Corp. warrants its non-consumable hardware products to be free from defects in materials and workmanship. The warranty covers the cost of parts and labor to repair the product. Please keep the shipping box for future use.
User Manual Fire ID TM-801-EN 6.4. Shipping The Fire ID is a solidly built system designed to survive shipping around the world. However, in order to avoid damage during shipping, the Fire ID must be properly packaged. In general, the best way to package the Fire ID is in the original factory container. If this is no longer available, we recommend that user carefully wraps the Fire ID in at least 75 mm (3 inch) of foam or bubble pack sheeting.
User Manual Fire ID TM-801-EN Chapter 7. Technical Assistance If user has any questions about installing or using the device, contact your 3D Imaging & Simulations Corp representative or your local dealer. 3D Imaging & Simulations Corp. 815, Tamnip-Dong, Yuseong-Gu, Daejeon, Korea Tel : 82-42-931-2100 Fax : 82-42-931-2299 www.3DISCimaging.
User Manual Fire ID TM-801-EN Appendix I Installation Report Please complete this report at the time of installation and submit the completed form signed by customer to: Fax : +82-42-931-2299 E-mail : support@3DISCimaging.