User Manual Computed Radiography Scanner Doc No. : TM -701 Rev 0.1.4 18.Oct.2011 Part No. : CR-FPM-01-001 3DISC, FireCR, Quantor and the 3D Cube are trademarks of 3D Imaging & Simulations Corp, South Korea, and its affiliates. All other trademarks are held by their respective owners and are used in an editorial fashion with no intention of infringement.
User Manual FireCR TM-701 Contact 815, Tamnip-Dong, Yuseong-Gu, Daejeon, Korea Tel : 82-42-931-2100 Fax : 82-42-931-2299 Website : www.3DISCimagning.com E-mail : info@3DISCimaging.com 3DISC Americas 45921 Maries Road, #190 Dulles, VA 20166 USA Tel : 1-703-430-6080 E-mail : sas@3DISCimaging.com 3DISC Europe Gydevang, 39-41, 3450 Alleroed, Denmark Tel : 45-88-276-650 E-mail : twe@3DISCimagning.
User Manual FireCR TM-701 INFORMATION TO USER: The device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. NOTE : This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
User Manual FireCR TM-701 Warnings and Used Symbols To ensure the safety of patients, staff and other persons, any changes to software and hardware delivered by 3D Imaging & Simulations Corp. may only be made with prior written permission from 3D Imaging & Simulations Corp. Please read the respective manuals of the connected software, such as acquisition and diagnostic software, before starting to use the FireCR system.
User Manual FireCR TM-701 General Safety Guidelines All the safety and operating instructions should be read carefully before this device is operated. This device has been designed and tested to meet strict safety requirements applicable to medical equipment, and has been supplied in a safe condition. To ensure personnel and patient safety, the device shall be operated and serviced in compliance with all procedures, warnings and precautions during all phases of operation and service of this device.
User Manual FireCR TM-701 If any of the following conditions occur, unplug the device from the electrical outlet and contact authorized service personnel. The power cord or power adapter is damaged. An object has fallen into the device. The device has been exposed to water. The device has been dropped or damaged. The device does not operate correctly when the operating instructions are followed.
User Manual FireCR TM-701 Index of contents Chapter 1. Introduction ..................................................................... 9 Chapter 2. Unpacking ......................................................................11 2.1. 2.2. 2.3. Inspection for Damage ....................................................................11 Unpack the Shipping Container .......................................................11 Identify the Components .......................................................
User Manual FireCR TM-701 5.3. Guidance and Manufacturer ’s Declaration – Electromagnetic Immunity ..................................................................................................... 34 Chapter 6. Warranty and Repair Service ........................................ 35 6.1. 6.2. 6.3. 6.4. Standard Warranty.......................................................................... 35 Repair Service ................................................................................
User Manual FireCR TM-701 Chapter 1. Introduction Thank you very much for deciding on FireCR – Computed Radiography Scanner. The FireCR System is ideal for a wide range of Computed Radiography examinations in specialty practices such as chiropractors, podiatrists and orthopedists.
User Manual FireCR TM-701 Main Features State-of-the-Art Scanning Mechanism FireCR adopts state-of-the-art scanning mechanisms using high beam delivery efficiency optics module to construct its compact and rigid structure. High Throughput Its unique and patented dual direction scanning mechanism enables to improve the efficiency and high throughput. Scanning Resolution User selectable resolution of 100m and 200m allows user to make diagnosis on variable purposes.
User Manual FireCR TM-701 Chapter 2. Unpacking 2.1. Inspection for Damage FireCR is shipped in a custom designed container to protect the scanner from external shock. Before unpacking the scanner, inspect the shipping container for damage. In case the container is damaged, notify the shipper immediately. 2.2. Unpack the Shipping Container Open the shipping container by rotating the butterfly shape lock and remove items from the container. Butterfly shape lock Figure 1.
User Manual FireCR TM-701 Open the shipping container, and remove the scanner and accessories as described below. Pouch for cassette, manual and software CD Space for power adapter, power cord and USB cable Strap for scanner removal Figure 2. Inside of Shipping Container Pull two straps to remove the scanner. And remove the cassette, manuals and Acquisition and Diagnostics Software CD from the pouch attached to the lid.
User Manual FireCR TM-701 2.3. Identify the Components Identify each of these components. Part No. Item CR-FP-01-00X FireCR CR Scanner CR-FP-02-003 Universal Cassette 14” x 17” containing IP size 14” x 17” CR-FP-02-004 Universal Cassette 14” x 10” containing IP size 10” x 12” CR-FPA-01-001 Power Adapter CR-FPA-02-001 USB 2.
User Manual FireCR TM-701 10” x 12” Cassette (Imaging Plate Included) 14” x 17” Cassette (Imaging Plate Included) USB 2.0 Interface cable FireCR User manual Power cord Power adapter Transportation case Figure 3.
User Manual FireCR TM-701 WARNING Use of Power Cord; Type SJT or SVT, min. 18AWG, 3-Conductor, VW-1 125V, min 10A (or 250V, 10A). Max 3.0m long; One end with Hospital Grade Type, NEMA 5-15P for 125V or NEMA 6-15P for 250V. Other end with appliance coupler. “CAUTION Grounding reliability can only be achieved when the equipment is connected to an equipment receptacle marked “Hospital Only” or “Hospital Grade”.
User Manual FireCR TM-701 Chapter 3. Setting Up WARNING Unsuitable Installation Sites Locations with excessive humidity or dust Locations subject to high temperature Locations subject to shaking or vibration Locations exposed to considerable electrical or magnetic noise, or other forms of electromagnetic energy Locations with poor heat radiation 3.1.
User Manual FireCR TM-701 In case that desk or table is not flat, adjust feet under the scanner for leveling. The scanner weighs approximately 30 kg (65 lbs) and requires two persons to lift. Carefully place the scanner into its final position. Adjustable foot Figure 5. Scanner Leveling DANGER Never place the scanner on the floor. Sliding the scanner may result in internal damage or misalignment of the optics. Install in a location that is level and stable.
User Manual FireCR TM-701 WARNING Do not place anything on top of the scanner. WARNING This equipment may be interfered or interfere by electromagnetic or other interference. Assure a distance of minimum 1.0 m with neighboring equipment. 3.2. Wall Mount (Option) The FireCR can be mounted on the wall to save space occupancy. When purchasing the wall mount kit, a detailed installation guide and all parts necessary for assembly are provided.
User Manual FireCR TM-701 DANGER 3D Imaging & Simulations Corp. is not liable for product damage or personal injury when the user fails to follow the product installation instruction. WARNING Pulling, pushing, or climbing on the system may cause the system fall. Free space of 50 cm (20 inch) on top side, at least, for cassette insertion and ejection. Front Side Free space of 10 cm (4 inch) on sides, at least.
User Manual FireCR TM-701 3.3. Identify Important Features Look over the scanner and features shown in this section. User will need to know where these features are when user operates the scanner in later chapters. 3.3.1. Scanner Connecting Part Power Switch USB 2.0 Port Power Inlet Figure 7. Scanner Important Features 3.3.2. Scanner Status Indication LED Indication LED shows the status of the scanner as described below.
User Manual FireCR TM-701 Status Indication LED Figure 8. Scanner Status Indication LED 3.3.3. Scanner Reset Button In case that the scanner is stuck during scanning, push scanner reset button by sharp pin to initialize the scanner. Scanner Reset Button Figure 9.
User Manual FireCR TM-701 WARNING Do not push scanner reset button during scanning. 3.4. Computer Requirements 3.4.1. Recommended Requirement Operation System CPU Memory Microsoft Windows XP (32bit) or 7 (32bit) Core Duo / Core2 Processor RAM 4GB or more Hard Disk 300GB Free Hard Disk Space Network Video Video Resolution 1Gbps Ethernet 32 bit Color Display 1280 x 1024 3.4.2.
User Manual FireCR TM-701 3.6. Connect the Cable and Power Cord 3.6.1. Connect Interface Cable The scanner interfaces with computer via USB2.0 cable. 1. Use the USB cable in the shipping container. 2. Connect the cable to the scanner’s USB2.0 port, located on the rear of the scanner. 3. Connect the other end of the cable to the USB2.0 port on the computer. Figure 10. USB Connection DANGER This equipment is indoor use only and all the communication wirings are limited to inside of the building.
User Manual FireCR 3.6.2. TM-701 Connect the Power Cord 1. Connect the power cord to the scanner, located on the rear side. 2. Connect the other end of the cord to a grounded power outlet. Figure 11. Power Connection DANGER This equipment must only be connected to supply mains with protective earth. Use only a three-wire cord that has grounding. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet.
User Manual FireCR TM-701 WARNING Socket-outlet shall be installed near the device and shall be easily accessible. Do not place the device where difficult to access to appliance inlet. Do not unplug the power cord or turn the power switch off during scanning. 3.6.3. Installation Report After installation of the scanner, fill in Installation Report from (Appendix I) and send to 3D Imaging & Simulations Corp. service department by fax or e-mail. Fax : +82-42-931-2299 E-mail : support@3-disc.
User Manual FireCR TM-701 Chapter 4. Operating 4.1. System Specifications Sampling Pixel Pitch Pixel Matrix (IP 14” x 17”) Pixel Matrix (IP 10” x 12”) Standard 200um High 100um Standard 1750 x 2150 High 3500 x 4300 Standard 1250 x 1500 High 2500 x 3000 Accepted Cassette Size 14” x 17”, 14” x 10” Gray Scale Resolution 16 bit Eraser Embedded Computer Interface USB 2.0 Dimensions 117 (H) x 464 (W) x 703 (D) mm 4.8 (H) x 18.3 (W) x 27.
User Manual FireCR TM-701 4.2. Operation Conditions Indoor use only Operating Temperature 15C ~ 30C (59F ~ 86F) Temperature Gradient 0.
User Manual FireCR TM-701 4.3. Operating Instructions 4.3.1. Turn on the Scanner Turn on the scanner. Power switch is on the rear side of the scanner. DANGER This device uses laser. Avoid looking inside of the scanner. 4.3.2. Turn on the Computer Turn on the computer. Acquisition and Diagnostic Software must be installed before operate the scanner. 4.3.3.
User Manual FireCR 4.3.5. TM-701 Circuit Functions Figure 11. Circuit diagram Base Board: Base board is a controller of peripherals. It controls peripherals upon command of core board. Peripheral: This is peripherals for image acquisition.
User Manual FireCR TM-701 Chapter 5. Symbols Symbol Description Warning, Consult Accompany Documents. Manufacturer ON Equipment Power On OFF Equipment Power Off Date of Manufacture FCC ID : X68CRSCANNER1 FCC Mark Medical Equipment WITH RESPECT TO ELECTRIC SHOCK FIRE, AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL60601-1 / CAN / CSA CSS.2 No. 601.
User Manual FireCR TM-701 5.1. Manufacturer’s Declaration - Electromagnetic Emission The FireCR system is intended for use in the electromagnetic environment specified below. The customer or the user of FireCR system should assure that it is used in such an environment Emission test Compliance RF emissions Group 1 CISPR 11 Electromagnetic environment - guidance The FireCR system uses RF energy only for its internal function. Therefore.
User Manual FireCR Power frequency (50/60Hz) Magnetic field IEC 61000-4-8 TM-701 3.0 A/m 3.0 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. Voltage dips, short <5% Uт (>95% dip in Uт) <5% Uт (>95% dip in Uт) Mains power quality should be Interruptions and for 0.5cycle for 0.5cycle that of a typical commercial or hospital environment.
User Manual FireCR TM-701 Note 1) Uт is the A.C. mains voltage prior to application of the test level. Note 2) At 80 MHz and 800 MHz, the higher frequency range applies. Note 3) These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
User Manual FireCR TM-701 5.3. G u i d a n c e a n d M a n u f a c t u r e r ’ s D e c l a r a t i o n – Electromagnetic Immunity The FireCR system is intended for use in the electromagnetic environment specified below.
User Manual FireCR TM-701 Chapter 6. Warranty and Repair Service 6.1. Standard Warranty 3D Imaging & Simulations Corp. warrants its non-consumable hardware products to be free from defects in materials and workmanship. The warranty covers the cost of parts and labor to repair the product. Please keep the shipping container for future use. Products returned to the factory for repair should be properly packaged. To obtain warranty service, follow the procedure described in the Repair Service section.
User Manual FireCR TM-701 6.4. Shipping The FireCR is a solidly built system designed to survive shipping around the world. However, in order to avoid damage during shipping, the FireCR must be properly packaged. In general, the best way to package the FireCR is in the original factory container. If this is no longer available, we recommend that user carefully wraps the FireCR in at least 75 mm (3 inch) of foam or bubble pack sheeting. The wrapped device should then be placed in a sturdy cardboard carton.
User Manual FireCR TM-701 Chapter 7. Technical Assistance If user has any questions about installing or using the device, contact your 3D Imaging & Simulations Corp representative or your local dealer. 3D Imaging & Simulations Corp. 815, Tamnip-Dong, Yuseong-Gu, Daejeon, Korea Tel : 82-42-931-2100 Fax : 82-42-931-2299 www.3-disc.
User Manual FireCR TM-701 Appendix I Installation Report Please complete this report at the time of installation and submit the completed form signed by customer to: Fax : +82-42-931-2299 E-mail : support@3-disc.