Glass Break Detector 2GIG-GB1-345
The 2GIG-GB1-345 Glass Break Detector is a fully supervised, tamper-protected,
ceiling- or wall-mounted unit with 15 ft. maximum detection range, 360° maxi-
mum horizontal sensing angle, and dual-stage glass break detection.
Installation/Mounting & Programming Guidelines
To setup the glass break detector:
1. Hold the 2GIG-GB1-345 Glass Break Detector unit upside down and twist the
base counter clockwise to remove it.
2. Install recommended batteries making sure to observe the correct polarity.
3. Wait 5 seconds for the power up delay.
4. Enter the programming mode for a wireless device on the 2GIG alarm control panel.
5. Enroll the Glass Break Detector by pressing and holding the tamper switch for 2
seconds (see
Figure 4
).
To Mount the glass break detector:
1. Place the Glass Break Detector base on the opposite wall or adjacent wall to
the window being protected.
2. Affix the base to the desired location utilizing the 3 long mounting screws with
anchors that are supplied. NOTE: For wall mounting the test button should be
oriented down nearest the floor.
3. When attaching the detector to the base, match the alignment marks and twist
clockwise. If batteries are not present, the red tabs must be held away from
the detector.
Testing
Walk Test
1. Push the test button for 2 seconds and then release it. The red LED will light while the button is pressed.
The green LED will blink once to indicate that the unit is in auto test mode for 90 seconds (see
Figure 1
).
2. Activate a glass break simulator in the area of the window or windows that you are attempting to protect
with the glass break detector. The Glass Break Detector should first acknowledge the detection of a thud
sound by illuminating the green LED and then illuminate the red LED when the unit detects the crash
portion of the glass breaking sound (see
Figure 1
).
RF Test
Push and hold the test button for 5 seconds and then release it. The red LED will light while the button is
pressed. The green LED will blink twice to indicate that the unit is in RF test mode for 90 seconds (see
Figure 1
).
Note: It is recommended that a system test be performed per the Operation & User’s Guide at least once a year.
Glass Type/Thickness
Minimum size for all glass types is 11” x 11” (28 cm x 28 cm) square; glass must be framed in the wall of the
room or mounted in a barrier of 36” (.9 m) minimum width.
Type Minimum to Maximum Thickness
Plate 1/8 in. to 1/4 in. (3.2 mm to 6.4 mm)
Tempered 1/8 in. to 1/4 in. (3.2 mm to 6.4 mm)
Sealed Insulating† 1/8 in. to 1/4 in. (3.2 mm to 6.4 mm)
† Sealed insulating glass types are protected only if both plates of glass are broken.
Battery Installation & Replacement
Remove the cover by twisting counterclockwise. Use only the recommended replacement batteries (see
Specifications
). Be sure to
observe the polarity.
WARNING! The polarity of the battery must be observed, as shown (See
Figure 4
).
Improper handling of lithium batteries may result in heat generation, explosion or
fire, which may lead to personal injuries. Replace only with the same or equivalent
type of battery as recommended by the manufacturer. (see
Specifications
)
Batteries must not be recharged, disassembled or disposed of in fire. Disposal of used
batteries must be made in accordance with the waste recovery and recycling regulations in your
area.
Keep away from small children. If batteries are swallowed, promptly see a doctor.
California Only: This Perchlorate warning applies only to Manganese Dioxide Lithium cells sold
or distributed ONLY in California, USA. Perchlorate Material-special handling may apply. See
www.dtsc.ca.gov/hazardouswaste/perchlorate.
Specifications
Wireless Signal Range 300 ft., open air, with 2GIG Wireless Alarm Control Panel
Code Outputs Alarm; Alarm Restore; Tamper; Tamper Restore; Supervisory; Low Battery
Transmitter Frequency 345.000 MHz (crystal controlled)
Transmitter Frequency Tolerance ± 15 kHz
Transmitter Bandwidth 24 kHz
Modulation Type Amplitude Shift Keying—On/Off Keying (ASK-OOK)
Unique ID Codes Over one (1) million different code combinations
Supervisory Interval 70 minutes
Peak Field Strength Typical 50,000 uV/m at 3m
Sensor Type Single microphone, dual stage thud, and crash
Mounting Height 7 ft. (2.13 m) Minimum to 10 ft. (3.05 m) Maximum
Sensor Range 15 ft. (4.57 m)
Maximum Horizontal Sensing Angle 360° for ceiling mount or 180° for wall mount
Dimensions (DxH) 4.55 x 1.9 in. (11.56 x 4.83 cm)
Weight (including battery & bracket) 5.1 oz. (144.6 g)
Housing Material ABS plastic
Color White
Operating Temperature 32° to 120°F (0° to 49°C)
Relative Humidity 5-95% Non-Condensing
Battery (included, not installed) Two (2) Panasonic CR123A, or equivalent Lithium batteries
Regulatory Listing(s) ETL, FCC Part 15, Industry Canada
Approved Glass Break Simulator Intellisense FG-701
Warranty* Two (2) years
Included Accessories Three (3) Phillip’s head screws, three (3) plastic wall anchors
FCC COMPLIANCE STATEMENT*
This device complies with FCC Rules and Regulations as Part 15 devices, as well as Industry Canada Rules and Regulations.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
Note: Changes or modifications to the device may void FCC compliance.
FCC ID: WDQ-GB1345
Industry Canada ID: 7794A-GB1345
*For more warranty and compliance information, visit our website (www.2gig.com).
Figure 4
Figure 3
Operating Instructions
Technical Support:
1-866-670-1591
www.2gig.com
187-0721 Rev. B
Figure 2
Figure 1
©2009 2gig Technologies Inc. All Rights Reserved
*Note: When wall mounted, the Glass Break Detector is designed to provide coverage on the opposite or adjacent windows and not windows on
the same wall as the Glass Break Detector.
Ceiling
Mount
Wall
Mount*

Summary of content (1 pages)