User Manual

1 Copyright © 2018 Nortek Security & Control LLC
PRINTER’S INSTRUCTIONS:
INSTR, INSTL,2GIG-DW30-345 - P/N: 10021755A - INK: BLACK - MATERIAL: MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500 " X 11.00" - TOL: +/- 0.125”- SCALE: 1-1 - FOLDING: 4X TO 1.5" x 2" FINISH WITH LOGO SHOWING - SIDE 1 OF 2
2GIG-DW30-345
OUTDOOR WIRELESS CONTACT SENSOR MANUAL
Installation Instructions
The Outdoor Wireless Contact (2GIG-DW30-345) is designed for installation on gates, doors, and other items that open and close.
It communicates with the control panel using the 345
MHz frequency. When the magnet (which is mounted
near the sensor) moves away from or closer to the
door contact’s sensor, signals are transmitted to the
control panel. The sensor also has an external input
that accepts connections from Normally Closed (NC)
dry contact devices. For added protection, it is also
equipped with a cover and wall tamper.
Box Contents
Outdoor Sensor
Magnet
Lithium AA Batteries (2x)
Mounting screws
Installing the Batteries
1. Loosen the cover screw.
2. Choose any pry point, then use a small screwdriver to
remove the Sensor Mounting Plate
3. Remove the Sealing Cover.
4. Install the two Lithium Ion batteries.
5. Align the Sealing Cover to the screw hole in the sensor cover,
then press to close.
6. Engage Sensor tabs into mating holes in Sensor Mounting
Plate and swing closed. Secure with cover screw.
Mounting Guidelines
Mount the Sensor within 100 ft (30 m) of the control panel. Although the transmitter may have a range of 350 ft (106.7 m) open
air, the sensor location can have a significant effect on range. In open / unobstructed situations, the transmitter range may be
greater. In adverse wireless conditions, changing the sensor orientation may lead to improved range.
Testing the Outdoor Wireless Contact
Before mounting the Outdoor Wireless Contact at the desired location, perform a walk test to verify that it can establish good
Radio Frequency (RF) communication with the control panel.
Utilize a Repeater (P/N: 2GIG-RPTR1-345) if the RF communication is insufficient for the desired location.
NOTE: To fully test the Outdoor Wireless Contact, see the control panels Installation and Programming Guide.
Mount the device on a vertical surface (at a sufficient height) where water, snow and ice buildup won’t interrupt operation.
NOTE: Adding silicone caulk surrounding the rubber wire seal on the Sealing Cover will increase protection against water.
Mount the Magnet on the magnet sensing side of the Sensor. On wooden surfaces a gap of approximately 2” is possible.
This will be decreased when mounting on metal surfaces.
Mount the Sensor on the stationary surface, and mount the Magnet on the moving surface.
Mount the Magnet and Sensor parallel with one another.
If installed on a wooden surface, mount the sensor and magnet on the inside of the structure (if possible).
NOTE: Use screws suitable for the mounting surface.
If mounted on a curved surface, use zip ties and/or suitable screws to fasten the Sensor and Magnet.
Tamper Protection:
The tamper switch will activate if the cover is removed or if the sensor is detached from its mounting location.
Pry points
out-door-sensor_batteries
SENSOR
SEALING
COVER
SENSOR
MOUNTING
PLATE
MAGNET

Summary of content (4 pages)