User Manual

Recessed Door Contact 2GIG-DW20R-345
The 2GIG-DW20R-345 is the industry’s most flexible supervised recessed door/window contact,
allowing a multitude of applications while hiding the transmitter within a door or window frame.
The 2GIG-DW20R-345 uses a replaceable lithium battery and should last 5 years under normal
usage.
Installation & Mounting Guidelines
It is important to select the proper placement of the recessed transmitter and magnet. The
transmitter comes with two different tops, however, the screw mount is recommended for
securing the sensor to the door frame. The magnet does not have a second top with a flange to
screw it into place so you must be extra careful to ensure that the magnet is tightly in place
once installed.
1. Install the recommended battery if it is not already installed (see
Battery Installation &
Replacement
).
2. Select a location on the door or window frame for the 2GIG-DW20R-345 transmitter and magnet to be
installed. Use a marker to mark and ensure that the two holes you intend to drill are lined up directly
across from each other.
3. Using an 11/16" drill bit, slowly drill the first hole for the transmitter. The 2GIG-DW20R-345 was specifi-
cally designed to be slightly larger than an 11/16" hole so you will need to carefully drill to fit by slowly
routing the hole little by little to ensure a snug fit. Use the flanged cap and use the included screws for
mounting the transmitter to the door or window frame.
4. Drill the matching hole for the magnet, directly opposite from the transmitter in the door, also using an
11/16" drill bit.
Programming
Refer to the
2GIG Installation & Programming Instructions
wireless devices for 2GIG contacts.
2GIG panels allow a tamper to be sent to ‘LEARN’ the serial code of the transmitter. The 2GIG-DW20R-345
sends a tamper Fault and Restore when the battery is installed. To learn the contact into a 2GIG panel
insert the battery while the panel is in ‘LEARN’ mode. If inserting the battery does not learn in the
contact to the panel, use the supplied magnet to learn in the contact.
Testing
Before mounting the sensor, verify that the sensor mounting location provides good RF communication
to the panel. To verify, do the following:
1. Put the control panel into sensor test mode.
2. Hold the magnet next to the removable cap on the sensor and then pull the magnet away from
the sensor.
3. Listen for siren or keypad beeps to determine appropriate response (refer to the control panel
installation instructions).
4. Exit sensor test mode.
Note: It is recommended that a system test be performed per the Operation & User’s Guide at least
once a year.
Battery Installation & Replacement
Use a flat head screw driver to pry open the top of the 2GIG-DW20R-345 to change tops or access the battery.
Use care when installing the battery and observe the correct polarity when the battery is inserted (see
Figure 2
). Use only the
recommended replacement batteries (see
Specifications
).
WARNING! The polarity of the battery must be observed, as shown (see
Figure 2
). Improper handling of lithium
batteries may result in heat generation, explosion or fire, which may lead to personal injuries. Replace only with
the same or equivalent type of battery as recommended by the manufacturer. (see
Specifications
)
Batteries must not be recharged, disassembled or disposed of in fire. Disposal of used batteries must be made in accor-
dance with the waste recovery and recycling regulations in your area.
Keep away from small children. If batteries are swallowed, promptly see a doctor.
California Only: This Perchlorate warning applies only to Manganese Dioxide Lithium cells sold or distributed ONLY in California,
USA. Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate.
Specifications
Wireless Signal Range 450 ft., open air, with 2GIG Wireless Alarm Control Panel
Code Outputs Alarm; Alarm Restore; Supervisory; Low Battery
Transmitter Frequency 345.000 MHz (crystal controlled)
Transmitter Frequency Tolerance ± 15 kHz
Transmitter Bandwidth 24 kHz
Modulation Type Amplitude Shift Keying—On/Off Keying (ASK-OOK)
Unique ID Codes Over one (1) million different code combinations
Supervisory Interval 70 minutes
Peak Field Strength Typical 50,000 uV/m at 3m
Reed Switch Magnetic Sensitivity 10 to 20 amp turns
Reed Sensitivity 0.625 in. (1.59 cm) minimum gap, 0.85 in. (2.16 cm) typical
Magnet Type Rare earth
Magnet Dimensions (HxD) 0.5 x 0.75 in. (1.27 x 1.9 cm)
Sensor Dimensions (HxD) 2.57 x 0.75 in. (6.53 x 1.9 cm)
Weight (including battery & magnet) 1.25 oz. (35.4 g)
Housing Material ABS plastic
Color White
Operating Temperature 32° to 120°F (0° to 49°C)
Relative Humidity 5-95% Non-Condensing
Battery (included, not installed) One (1) Panasonic CR2, or equivalent Lithium battery
Regulatory Listing(s) ETL, FCC Part 15, Industry Canada
Warranty* Two (2) years
Included Accessories Two magnetic cap styles (Normal and Screw type), two (2) Phillip’s flat-head screws
FCC COMPLIANCE STATEMENT*
This device complies with FCC Rules and Regulations as Part 15 devices, as well as Industry Canada Rules and Regulations.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
Note: Changes or modifications to the device may void FCC compliance.
FCC ID: WDQ-DW20345
Industry Canada ID: 7794A-DW20345
*For more warranty and compliance information, visit our website (www.2gig.com).
NOTICE: Before removing the circuit board,
notice that it fits inside a channel on the
inside of the case. When replacing the
board, ensure you fit it back into the same
channel for proper fit.
Circuit Board
Figure 2
Operating Instructions
Technical Support:
1-866-670-1591
www.2gig.com
IPM-1054-01 Rev. B
Figure 1
©2009 2gig Technologies Inc. All Rights Reserved

Summary of content (1 pages)